The best fecal sewer pumps 2022
Problems with communications in a private house are not limited to plumbing and electricity. No less serious is the task of waste disposal

To remove sewage, a septic tank is usually used, in extreme cases – a cesspool. They are periodically cleaned by calling a special vacuum machine. But this is not a cheap operation, it is much more economical and reliable to pump the contents into the nearest sewer network. To do this, use pumps of a special design, the so-called “fecal”. They are also suitable for removing food residues and other non-solid waste.

Top 10 rating according to KP

Editor’s Choice

1. FOUR ELEMENTS ПРОФ Sewage 1100F Ci-Cut

Reliable and durable unit with a vertical installation, equipped with a chopper, a float switch, as well as protection against dry running and overheating. Pumps liquid with solid particles up to 15 mm in diameter. Manufacturer’s warranty – 1 year.

Specifications:
Performance:13,98 mXNUMX/h
Effort:7 m
Immersion depth:5 m
The weight:24 kg
Advantages and disadvantages:
Chopper, cast iron work disc
Plastic spigot for hose
show more

2. STURM WP9775SW

Pumps liquid with solid particles up to 35 mm in diameter. The pressure allows the pump to be used with deep septic tanks. It has protection against dry running and overheating. Manufacturer’s warranty – 14 months.

Specifications:
Performance:18 mXNUMX/h
Effort:9 m
Immersion depth:5 m
The weight:14.85 kg
Advantages and disadvantages:
Full cast iron body, steel impeller, quiet operation
High position of the knife
show more

3. Belamos DWP 1100 DWP 1100 CS

Centrifugal pump with a knife that grinds particles with a diameter of up to 12 mm. Cast iron body and impeller. There are protection against dry running and overheating. Manufacturer’s warranty – 1 year.

Specifications:
Power:1100 W
Performance:14 mXNUMX/h
Effort:7 m
Immersion depth:5 m
The weight:24 kg
Advantages and disadvantages:
Cast iron body and impeller
Large weight
show more

What other fecal sewer pumps are worth paying attention to

4. Jilex FEKALNIK 260/10 N

Low power consumption – the advantage of this unit when used in the country, where the power grid is usually weak. The maximum diameter of solid particles is 35 mm. Stainless steel housing, internal bearings are self-lubricating and maintenance free.

Specifications:

Power:800 W
Performance:16,6 mXNUMX/h
Effort:10 m
Immersion depth:8 m
The weight:24 kg

Advantages and disadvantages

Powerful, quiet, reliable
Motor short circuit occurs
show more

5. Pedrollo BCm 15/50 (MCm 15/50) (1100 Vt)

The powerful unit pumps dirty water with particles up to 50 mm in diameter. Cast iron impeller and casing. There is protection against dry running and overheating.

Specifications:

Power:1100 W
Performance:48 cu. m/h
Effort:16 m
Immersion depth:5 m
The weight:7,6 kg

Advantages and disadvantages:

Quality build, quiet operation
Frequent stoppages during work
show more

6. WWQ NB-1500GM

The powerful drainage and fecal pump equipped with a grinder. Made from stainless steel and cast iron. The impeller is separated from the electric motor by an oil chamber with mechanical seals. The pump is equipped with automatics with protection against dry running and overheating and is designed for long continuous operation. Manufacturer’s warranty – 1 year.

Specifications:

Power:1500 W
Performance:28 mXNUMX/h
Effort:17 m
Immersion depth:5 m
The weight:23,5 kg

Advantages and disadvantages:

High performance, quality materials
Float switch set to liquid level too high
show more

7. Вихрь ФН-2200Л 68/5/6

The pump can be used continuously to clean septic tanks. The engine allows up to 20 on / off per hour. Solid particles up to 15 mm in diameter are crushed with a steel knife. Manufacturer’s warranty – 1 year.

Specifications:

Power:2200 W
Performance:30 mXNUMX/h
Effort:18 m
Immersion depth:9 m
The weight:23,5 kg

Advantages and disadvantages:

Constant pumping speed, excellent knife, body does not corrode
Not found
show more

8. JEMIX GS 400 (400 W)

Compact, inexpensive pump for temporary toilets in the country or camping. The case is plastic. Equipped with a float switch for dry running protection.

Specifications:

Power:400 W
Performance:7,7 mXNUMX/h
Effort:5 m
Immersion depth:5 m
The weight:7,6 kg

Advantages and disadvantages:

Light weight, inexpensive, compact
Weak, poorly pumps heavily polluted liquid
show more

9. UNIPUMP FEKACUT V1300DF (1300 Вт)

A reliable device designed for pumping out sewerage without fibrous inclusions. Worked well in small septic tanks.

Specifications:

Power:1300 W
Performance:18 mXNUMX/h
Effort:12 m
Immersion depth:5 m
The weight:7,6 kg

Advantages and disadvantages:

High performance, quiet operation
Not found
show more

10. Caliber NPC-1100U Aqua Line

Inexpensive model for temporary use in the country. Pumps liquid with particles up to 40 mm in size. Equipped with protection against dry running and overheating. Includes a universal fitting for hoses of different diameters.

Specifications:

Power:1100 W
Performance:20 mXNUMX/h
Effort:9 m
Immersion depth:7 m
The weight:7,6 kg

Advantages and disadvantages:

Includes adapters for different hoses, quiet operation
Doesn’t handle viscous liquids well
show more

How to choose a fecal sewer pump

Choosing a fecal pump is not a trivial task, although, at first glance, it is very simple. Healthy Food Near Me asked Maxim Sokolov, an expert at the VseInstrumenty.ru online hypermarket, to talk about the nuances of choice. But first, let’s figure out how such a pump works and what types of such pumps are.

The device of fecal pumps

The specific operating conditions of this equipment dictate its design features. It is necessary that it fails as rarely as possible and works reliably without maintenance. In fact, this is a self-priming circulation pump with additional elements.

The sewage grinder is installed in front of the working chamber and is equipped with stainless steel knives. Its task is to prevent large fractions from entering the pump and outlet pipe. This device is especially important in the sewer systems of cafes and restaurants, in which food residues can tightly clog the outlet pipe, cleaning it will require considerable effort and expense. A pump for cleaning a home septic tank can do without a chopper.

Seals and oil chamber

The conventional pump is cooled by the pumped water. The environment where the fecal pump operates is not so heat-conductive and the device may overheat. To avoid an accident, the design has a so-called oil chamber between the electric motor and the working chamber, where the impeller rotates and the necessary pressure is created. The shaft passes through a container filled with machine oil, seals-glands on both sides block the possibility of penetration of impurities to the electric motor.

Types of fecal pumps

In accordance with the design features, fecal pumps are divided into the following types:

  • submersibles descend on a cable to the bottom of a sewer well, septic tank or cesspool. They are installed vertically, the inlet is at the bottom, the outlet is connected to a pipe that goes to the surface. The design of such devices is as strong and durable as possible, the body and the impeller are made, as a rule, of thick chemically neutral plastic. Such pumps are equipped with a float sensor, which is necessary to turn off the electric motor when the liquid level drops below a certain level.
  • Semi-submersible pumps are designed so that the working chamber is below the liquid level, and the electric motor is above it. Sometimes they are equipped with a cutting mechanism. Such units are designed for use in cesspools.
  • Surface fecal pumps stand on the ground and suck sewage through a pipe immersed in them. The maximum size of solid particles for such pumps is up to 5 mm, their power is small. But the dimensions of the device are small, and the cost is much lower than that of fully submersible models.

What to look for when choosing a fecal pump

The main factors that determine the choice of a particular model of a fecal pump:

  • Permanent maintenance of a private sewer system with a cesspool or septic tank is possible only by installing a submersible, in extreme cases, a semi-submersible unit. If the pump is turned on occasionally, for example, in the country, then a surface design is sufficient.
  • The volume of pumped sewage is determined based on the volume of the tank and the speed of its filling. A float switch is required to prevent dry running.
  • The depth of immersion is determined by the depth of the septic tank or cesspool. This parameter is necessarily indicated in the device passport, you need to choose a model that corresponds to the actual working conditions.
  • The maximum liquid temperature is also recorded in the device passport.
  • Crusher of large particles. The volume of sewage water may contain sufficiently large fragments that can jam the impeller and block the outlet pipe. An inlet grinder will help extend the life of the pump.

A fecal pump is necessary for organizing a comfortable life in a private house. The models described here are suitable only for domestic needs; a completely different technique is used at powerful urban wastewater treatment plants. But without a domestic fecal pump, it will never be possible to organize a comfortable life in a private house far from civilization.

Leave a Reply