The modern arrangement of gas equipment facilitates operation. If one of the parts fails, you do not have to diagnose the entire system. Self-diagnostics of the Solly boiler will give errors on the display before you have time to know about the breakdown. The decoding of the symbols will indicate where to look for the malfunction.
The device, the principle of operation of the boiler Solly
The brand is represented by three series:
- Solly standard.
- comfort.
- First.
The combustion chamber of the Solli double-circuit boiler can be of open and closed type. In the latter case, the fan has a front and rear bearing, which ensures a long service life of the equipment. Some models are equipped with a bithermic heat exchanger. The difference in design in the structure is “tube in tube”. One of them circulates water for the heating system, the other – for hot water in the taps.
The steel burner does not corrode, and the operation of the circulation pump is regulated in three positions. The gas boiler control board is enclosed in a plastic box. It protects it from moisture and heat. Push-button control of the device. The display shows temperature indicators, error codes.
Errors and malfunctions
Incorrect connection and operation, untimely maintenance lead to problems in the operation of equipment. Rarely – factory marriage, low-quality spare parts. As a result, the boiler is blocked, and a code is displayed on the screen. The value can be found in the instructions and our table.
Display code | Which means | Trouble-shooting |
cs | Incoming thermostat failure. | Check the sensor, its contacts. Tighten the connections to the control board, install a new cable or thermostat if damaged. Diagnosis required:
Problems with the control module require a call to the wizard. |
dh error | Ignition problems. | What to do:
In case of interruptions in the system, you should wait for the supply to be restored. |
dy | Voltage fluctuations in the network. Deviation from the norm >187 V, | Connect the stabilizer to normalize the voltage. |
yl | The pressure in the system drops. |
|
fy error | Fan operation problems. The blades do not rotate. |
|
gs error | The radiator overheated, difficulties in the operation of the pressure switch. | Verify that the temperature sensor and pump wiring is correct. Replace pump if damaged. Clean the filters from dirt. Clean the heat exchanger from scale. Plaque interferes with the normal circulation of water, so the temperature rises. |
sy | Malfunction of the DHW temperature sensor. |
|
CO | Problems with settings. |
|
hs | The temperature sensor on the return line has failed. | Diagnose and replace. |
ls | The controller on the input line is defective. |
Carry out maintenance checks once a year. Clean the radiator and other parts from scale and dirt, monitor the condition of the chimney and the presence of draft. Adjust the boiler according to the instructions. If you are not sure that you can fix the equipment yourself, it is better to contact a service center.