Do you operate gas heating equipment? Then you know that even reliable units can fail. If the Hephaestus boiler displays an error code, then there is a problem in the system. The protective automation sends a signal to the control module, which displays a code on the display. Each character set represents a specific problem. What? We have detailed in the table.
Features of operation of the Gefest gas boiler
The equipment is represented by two series: Star and Econom. Power ranges from 16 kW to 32 kW. These are dual models. The heating heat exchanger is made of copper in the form of a curved tube. The secondary radiator for hot water supply (DHW) is also copper. But its design consists of several plates.
The steel burner is ignited by a piezoelectric element. The closed combustion chamber turns on the fan. It forcibly removes carbon monoxide. A coaxial chimney is connected to the chamber. It consists of two tubes, through one of which smoke is removed, and through the other air enters to maintain the flame. The chimney is led through a hole in the wall.
The circulation pump has three adjustable speeds. Includes air vent. Therefore, air jams in the system are extremely rare.
A 6 liter membrane tank is part of the design. It accepts excess liquid when heated. Safety automation protects the user from emergencies.
Errors and malfunctions
As soon as the self-diagnosis system displays an error code, rule out a system failure. To do this, restart the boiler. After turning it back on, check if the icons light up again or not. If yes, then look at the instructions or study our table.
Malfunction code | Which means | How to fix it yourself |
Error E1 | The water pressure in the circuit has dropped. |
|
Error E2 | Problems with ignition and maintaining the flame. | What to do:
Install new elements in place of broken parts. |
Error E6 | Problems with the removal of combustion products. | How to proceed:
|
E7 | The overheating protection (coolant temperature sensor) has tripped. | First of all, check the temperature sensors and their connections. If overheating really happened, check:
|
HER | The user entered erroneous numbers. | Recheck the specified values. |
Other faults
If you occasionally use the boiler, the pump may not start after a long period of inactivity. In this case, remove its plug and turn the shaft counterclockwise. Restart the boiler.
To avoid scale accumulation in the heat exchanger, it is recommended:
- Install magnetic water softeners.
- Do not use a heating temperature above 55 degrees, since it is then that scale begins to actively deposit.
Control the operation of heating equipment, conduct timely technical inspections.