Errors and malfunctions of the gas boiler Koreastar

Did the Koreastar boiler show errors on the display? This means that the self-diagnosis system “detected” a malfunction. All modern heating equipment is equipped with automation – sensors that control the operation of each unit. Sometimes the user does not even need to contact the service center. It is enough to determine the meaning of the code and find the problem.

Features of operation of Koreastar

The name of gas boilers “Koreastar” suggests that they are produced in Korea. But this is not so: they are produced in Europe, taking into account Russian conditions. Double-circuit models work stably with voltage drops in the network up to 15%.

Two heat exchangers provide heating for heating and hot water systems (DHW). Productivity reaches 13,6 liters per minute with a power of 32 kW. The heating capacity is designed for rooms with an area of ​​240 m².

Some models are equipped with bithermic radiators. They are designed according to the “pipe in pipe” type. At the same time, in one tube there is heating for hot water, in the other – for the circuit. Frost protection provided. The burner is equipped with a flame modulation system, so you can reduce the power at any time. Another feature of the burner is the pressurized type of operation, which makes the boiler quite noisy. You can read more about this in review of gas boilers “Koreastar”.

Error codes and malfunctions

In case of any malfunction in the operation of the boiler, the user must first look at the instructions. Most errors are listed by the manufacturer. It’s just not always clear how to fix them. We recommend restarting the equipment immediately:

  • Press the restart key;
  • Wait for the boiler to restart;
  • Make sure the characters have disappeared from the screen.

If nothing has changed, start looking for a breakdown. The table below shows solutions for different problems.

Fault codesWhat doesHow to fix it yourself
A01The system does not report the presence of a flame.
  • Unscrew the gas valve to the stop;
  • Check the gas valve for proper operation. The pressure should be 20 mbar;
  • Inspect the ionization electrode, its wiring for integrity. Strip its contacts during oxidation, replace. Pull the part to the burner at a distance of 3 mm.
A02A flame was reported, although there was no ignition.
  • Open the stopcocks, check if the valve opens;
  • Reboot the equipment;
  • Carry out diagnostics of the ignition and ionization sensor, restore their position in relation to the burner;
  • Make sure the integrity of the wiring, the tightness of the contacts of the sensors and the control board.
A03Overheating technology. Boiler operation is blocked. The temperature is over 90 degrees.

The thermostat has tripped. First of all check it for serviceability. Drain excess air from the system using Mayevsky taps.

Run diagnostics:

  • circulation pump. If it is faulty, replace or adjust the settings. Clean the impeller blades from blockage;
  • If the error is displayed again, repair the electronic module.
A08/F10The heating circuit temperature sensor is out of order.Checking the sensor, its connections and contacts. In the event of a short circuit (short circuit) or open circuit, a new element is installed.
F05Incorrect operation of the gas removal system.View:
  • Air relay connection;
  • Air diaphragm for sticking;
  • Fan performance.
  • Shafts or chimney pipes. It is often clogged with soot, soot. In strong winds, leaves and debris can get inside. For a complete cleaning, it is better to contact the utilities.
F11Hot water NTC temperature sensor failed.I got error F11, what to do:
  • Check the sensor for short circuit and open circuit.
  • Ring the contacts with a multimeter. Normally, the indicators are 10 kOhm.
  • Reconnect item. In case of breakage, connect a new element.

If ignition does not occur when DHW is turned on, inspect the three-way valve that switches heating between circuits.

F37Low pressure in the circuit (less than 80 kPa).Make sure the pressure sensor, its wiring is in good condition. Inspect all connections and assemblies for leaks. Any damage is sealed. Turn on water supply to the system.
F41The movement of the coolant is disturbed. The heat exchanger is overheating.How to fix the situation:
  • Inspect the heat exchanger for scale. Clean the tubes of deposits with reagents or citric acid. A layer of scale on the radiator interferes with water circulation, worsens heating, from which the unit overheats;
  • Bleed air from the pump. Set the appropriate mode. Install a new pump if it breaks.
F50The electronic board is not working.Checking grounding, boards for breakdown. It is better to entrust repair and replacement of the control module to a specialist.

Unfortunately, not all malfunctions of Koreastar heating equipment are displayed as a code on the display. Users complain that the devices are sensitive to voltage drops, which is why the control board often suffers. And this is despite the manufacturer’s assurances of stable operation at any jumps. Therefore, when choosing Koreastar, it is worth add a stabilizer.

Experts recommend annual preventive maintenance of breakdowns. Clean the unit from dirt, scale, conduct a technical inspection.