Error codes and malfunctions of the Navien gas boiler

You can pay only for the consumed resources and control the heating power with an autonomous heating system. Many residents of houses and apartments install boilers from the Korean manufacturer Navien. Despite the quality and duration of operation, even this technique is prone to breakdowns. We will list the errors of the Navien boiler and reveal their meaning. You will learn in which cases you can repair the device yourself, and when it is better to contact the master.

Features of the equipment

Equipment is wall and floor type. The most popular models are Navien Ice, Navien NCN SteelGA/GST, Navien AceTurbo and Ace Atmo, Navien LST. Among all the variety, you will find boilers with atmospheric and turbocharged combustion chambers. There are also condensing units with a built-in heat exchanger to collect condensate. Read more in the article “What is a gas condensing boiler”.

According to the type of operation, the units are divided into double-circuit and single-circuit. Double-circuit are equipped with two heat exchangers for heating water and space heating. All models have a Russified remote control, as well as sensors for monitoring systems.

The control circuit is equipped with a microchip, so the equipment is not afraid of power surges in the network. The design ensures stable operation when the pressure drops to 0,1 bar.

The built-in circulation pump will not allow the coolant to freeze even if the gas is turned off.

The boiler self-diagnosis system allows you to detect a breakdown at an early stage, as well as understand why a problem has occurred, how to fix it. Before proceeding with DIY repairs, make sure that the warranty period has expired. If you open the device, it will become invalid.

Decoding errors

How to troubleshoot? The repair instructions in our table will help.

Error CodesValueRepair by own hands
01EOverheating of attachments.
  • Diagnostics of the pump and its impellers, removal of blockages. Make sure the pump coil is working;
  • Bleed air from the heating circuit.
02ENot enough liquid in the heating circuit, pressure drops. Damaged flow sensor wiring.
  • Inspect connections for leaks;
  • Purge excess air from the system;
  • Start make-up until the mark rises 1,2–1,5 bar;
  • Diagnose the pump coil for a short circuit (short circuit);
  • Make sure the antifreeze in the circuit is correct for your boiler model. Otherwise, it must be drained and filled with water;
  • Inspect the flow sensor for serviceability;
  • Open the distribution valve.
Error 03 EThere is no message about the presence of a flame. The device does not start.
  • Open the gas valve;
  • Clean the ignition electrode, place it closer to the burner. Install the correct part.
04EThe system reports the presence of a flame, although no fuel is supplied to the burner.Diagnostics of the flame sensor, its contacts and connections. Connecting a working electronic board.
05EMalfunctions in the circuit of the heating temperature sensor and the electronic module.Inspection of wiring, circuit repair, tightening of contacts.
06EThe temperature sensor does not turn on. Short circuit.
07E/ 08EShort circuit of the DHW thermistor.
Error 09EThe fan is not working.It is required to check the motor and fan contacts. Carry out replacement if necessary.
Error 10EProblems with the removal of combustion products.What to do:
  • Clean the chimney from debris and soot;
  • Verify that the pressure sensor is working correctly;
  • See solution for 09E.
11E

Malfunction of the coolant filling sensor.

The code is typical for European-made models.

The reason may be a power surge.

If there was no jump, check the DIP switch settings – set the correct ones according to the instructions.

If this does not help, contact the service.

Error 13EThe flow controller in the heating circuit is out of order.Adjust the detail settings flag, clear it of blockage. Connect a new element.
12Problems with the functioning of gas fittings.
  • Cleaning nozzles from dust and soot;
  • Fuel pressure setting;
  • Drying of the electrode in case of water ingress;
  • Contacting a service center.
15Equipment failure.Reloading technology. Checking the connectors and wiring of the control board.
Error 16The overheat sensor has tripped.How to fix the problem:
  • Clean the heat exchanger from scale. You can buy a cleaning agent in a store, or make it at home from citric acid;
  • Adjust the pump regulator;
  • Reduce gas flow;
  • Diagnosis of the overheating sensor.
17Incorrect connection of DIP switches to the display.Reconnect.
18The smoke removal sensor is overheating.
  • Boiler restart;
  • Clean the chimney;
  • Remove ice from the coaxial pipe;
  • Replace sensor if broken.
27 (for Ice, Ice Coax)Problems with the air pressure sensor.Inspection of the sensor, its wiring, circuit, contacts.

Other malfunctions of the Navien boilers

Even if the codes on the display do not appear, and you notice malfunctions, proceed to eliminate them.

Why is the boiler noisy and buzzing

At the same time, hot water does not come out of the tap, or a thin stream flows. The reason is the blockage of the heat exchanger due to poor-quality water.

The water contains potassium and magnesium salts. When heated above 55 degrees, they are deposited on the nodes and parts, the walls of the radiator. The thicker the scale layer, the narrower the passage for water. Therefore, the pressure decreases, and the liquid boils. As a result, there is no hot water, extraneous sounds are heard. Due to poor heat dissipation, heating is often switched on, which leads to high fuel consumption.

How to be:

  • Rinse the heat exchanger, clean its tubes. Perform regular maintenance of the unit at least once a year;
  • Install a purification filter that will “soften” the water;
  • Do not set a high temperature – then the scale will not be deposited.

Heating does not work

If DHW heating is normal, but the heating circuit is not working, check the three-way valve. It switches the heating between the circuits. Perhaps it is jammed, or it is out of order. Carry out a replacement.

Remote control not working

Install new batteries.

Users of Navien boilers most often encounter such problems. If you follow the rules of operation and carry out regular preventive maintenance, you will be able to avoid many problems.