Refrigerators “Ariston” are not immune from malfunction. Modern technology consists of many components and parts that are controlled by an electronic module – the more complex the system, the more reasons lead to breakdown. Let’s consider them in the article.
Often the display will show an error. Its decoding indicates the cause of the problem, which you can try to fix with your own hands.
Common breakdowns of Hotpoint Ariston
Although Ariston refrigerators have proven to be reliable, problems sometimes occur. Well, if a fault code appeared on the display, then you can look into the instructions and calculate the breakdown. If this does not happen, and the device does not function normally, you can start the test mode. How to do this is also described in the user manual.
Common refrigerator problems:
- Noisy and buzzing while working.
- Makes strange sounds (cracks, clicks).
- There is no light in the chamber.
- Refrigerator does not cool, freezer does not freeze well.
- The freezer is very cold, the food freezes.
- Beeping, red light on.
- The motor-compressor does not turn off, it works without stopping.
- The compressor does not turn on.
- The back wall of the chamber freezes.
- Water at the bottom of the compartment.
Why such breakdowns occur and how to fix them, read below.
Hotpoint-Ariston Refrigerator Troubleshooting
Consider the main causes of problems and options for their solution.
Noisy refrigerator operation
If the two-chamber unit used to work normally, and recently it has begun to make a lot of noise, buzz, rattle, check:
- Correct installation. Whether the equipment is level, whether there is a skew. You can correct the situation by adjusting the front legs.
- Dishes in the chamber touch each other. When starting the engine, it rattles.
- The refrigerant circulates in the circuit and gurgling sounds may be heard. This is not a breakdown.
- Foreign objects or furniture come into contact with the unit body.
- Maintain a distance of at least 5 cm between the refrigerator body and walls and furniture.
Clicks and crackles during operation
Such sounds can indicate both the normal operation of the equipment, and problems that require repair. If the unit works normally and freezes, then:
- Clicks are possible when the motor is turned off. The materials of the chamber walls are deformed by the temperature difference.
- When starting and turning off the motor, the thermostat can click. In this case, the sounds should be from the first day of work.
Faults requiring repair:
- The electromechanical model clicks when turned on, but the motor-compressor does not work. There was a problem with the thermostat. It sends a message to the board about the increase in temperature in the chamber, then the board gives a command to turn on the motor. If the latter does not start, check the thermostat.
- The equipment turns on, the engine starts, but stops. The relay clicks off the motor. The compressor is defective and needs to be replaced. At the same time, the light is on in the department.
- The refrigerator clicks, the engine does not turn on, it is dark in the cell. The start relay has failed.
- Unit operates normally, but clicks are heard when the compressor is turned off. You need to check the motor fasteners, maybe they are loose.
No light in the department
Check the connection: whether the plug is firmly seated in the socket, press them tighter. If there is no light, replace the light bulb. Pay attention to the type of lighting and choose the appropriate model.
No cold in compartments
If there is an increased temperature in the chambers, the refrigerator can report this by blinking a red light or by sounding a squeak.
Refrigerator not cooling? Read the post “Refrigerator does not work” and also check:
- The tightness of the door to the body. Inspect the seal for integrity and suitability. If dirty, wipe it with soapy water and ammonia. If worn, replace element. Tighten the door fasteners.
- Frequency and duration of door opening. If you keep the doors open for a long time, warm air enters the chamber, which leads to an increase in temperature and condensation.
- Temperature controller. Is the correct value set?
When loading a large number of warm foods at the same time, you need to wait 20-30 minutes until the indicators are restored.
- Blockage of the capillary leads to a violation of the circulation of the refrigerant and a deterioration in cooling. It is better to call the wizard to fix the problem.
- Compressor failure. Error A2 may appear on the scoreboard. The refrigerator will consume a lot of electricity, and the production of cold will decrease.
Also, the reasons that the camera does not freeze could be:
- Defrost sensor failure.
- Evaporator heater failure.
- freon gas outlet.
- Incorrect operation of the electronic board.
Food in the compartment freezes
Need to check:
- Is the food touching the back wall of the refrigerator?
- Activate deep freeze mode. In this case, you need to disable it.
- The position of the thermostat. If the temperature is low, increase it.
A serious malfunction is a thermostat malfunction, then replacement and repair will be required.
Motor runs non-stop
Normally, the compressor runs intermittently, with “rest” shutdowns.
If it does not turn off at all and works for wear, then:
- The cell door does not close. The constant penetration of warm air leads to an increase in temperature. To restore performance, the engine runs without a break, pumping cold. Check seals and door position.
- The temperature in the room is above normal. Each model, including Ariston, has a climate class that indicates at what temperature it can be operated.
- Snow and ice build-up exceeds 2-3 mm. The heat transfer in the refrigerator is broken. Defrost the unit immediately.
Compressor does not start
There may be two possible faults.
The engine does not function, the light in the chamber is on:
- Problems with the operation of No Frost. It is recommended to contact the service center to find and solve the problem.
- Motor winding defective. Needs repair or complete replacement.
- The thermostat is not working. It is possible that the wiring between the regulator and the motor is broken. Diagnose and replace.
- Breakdown of the start relay.
- Main board defect.
The compressor does not turn on, the light is off:
- No light.
- The insulation of the power cord is broken, the socket is damaged.
All other reasons are identical to the first case.
Ice on the back wall
If a “fur coat” grows on the evaporator or on the walls, the cause may be a faulty thermostat.
You need to defrost drip-type models at least once every six months. For models with No Frost, the formation of ice is uncharacteristic. If this happens in the freezer, it’s a faulty defrost timer.
Water at the bottom of the refrigerator compartment
Products pressed against the back of the compartment accumulate condensate, which does not go into the drain, but flows down. Sort food and remove accumulated water.
It happens that the drainage hole is clogged with debris, crumbs, so the condensate has nowhere to drain. You can clean it with your own hands using a thin stick.
If you notice a malfunction in the Hotpoint-Ariston refrigerator, do not let things take their course. Try to figure out the causes and fix the problem or call the wizard.
The video will help repair the No Frost system: